Contingent Alarm
- Functions for Noise units only currently.
- Noise units are connected by their labels - set the same Red label on the primary and secondary unit.
- When a primary unit exceeds, it sets a tag in the database. If the secondary unit exceeds it then checks that there is a matching primary unit that exceeded recently. If there is, an email is sent.
Map page overhaul
- Full scale overhaul of the whole map page using a new clustering library.
- Positions are grouped by: Cluster of sites > individual site > cluster of positions > individual position / positions that share the same coordinate.
- A new panel has been added that is accessible from the left side of the map which allows for search functionality and selecting specific units.
- There is also an online and offline button to display only online or offline positions and sites (a site is online if at least one position is online).
Archived positions issue fix when directly swapping positions into a monitor.
Sound Insulation and Temporary Rehousing error on Day Week Month graph fixed.
- Leq and Third Octave were behaving differently but are now both functioning as intended.
Measurement interval error message removed for Weather and Vibra.
- Neither Weather nor Vibra use measurement intervals from the monitor profile and so do not use this functionality.
Send commands now function for Vibration units.
- Vibration commands code was out of date and has been brought up to modern standards.
Fixing firmware update button.
- Firmware api has been updated to a working URL and is undergoing additional testing.
Reveal password button added to login page.
Vibra units no longer have erroneous starting sample intervals of 0.
Prevented a unique error with VDV positions on a sub 1 minute measuremeent interval that change periods at midnight, resulting in buffered data not being uploaded correctly.
Separate Red and Amber labels for Noise (Broadband and Octave) limits
- Users can now set custom Red and Amber limit labels for use with the email alert system.
- If this is not required, Amber labels can still be left blank to retain the legacy Amber Warning message.
Sound Insulation exceedance counting graph comments
- Comments are now compatible with the Day Week Month view graph for Sound Insulation and Temporary Rehousing.
- They can be added and are displayed if existing from the Detailed View. It also correctly handles overlapping comments.
Email alerts for BS4142 Tonality graph
- Within the time period alerts menu, emails can be toggled on and off for users who have access to a position with BS4142 Tone Audibility Objective Method enabled.
- Emails read as “BS4142 Red Alert” and contain the frequency band, limit constraint and exceedance level.
SD card usage plot
- Similar to the existing battery usage graph, users may observe their SD card usage and a prediction of when its storage will run out.
Banner for new features
- A banner will display each time a new release is published with a link to the help centre’s New Feature’s page.